Skip to content
Now Shipping Worldwide

Slat Load Testing - PrimeAlux

This page summarizes a “Slat Load Test” document describing distributed load testing on two slats in defined configurations. The test explores both horizontal and vertical load effects, using an H+ reinforcement rail in the described setup.

Test setup

The document describes testing intended to find maximum load for two slats:

Slat size: 4″ × 0.8″ (100 × 20 mm), supported with reinforcement rail (H+), across panel spans of 6′, 5′ and 4′.

It also describes horizontal-only testing for 3.2″ × 0.8″ (80 × 20 mm) and 1.6″ × 0.8″ (40 × 20 mm), across the same spans.

Load results — horizontal (maximum distributed load on two slats)

Slat size6' span5' span4' span
100 × 20 mm (H+ reinforced)220 lbs319 lbs363 lbs
80 × 20 mm209 lbs275 lbs330 lbs
40 × 20 mm143 lbs187 lbs264 lbs

Load results — vertical (maximum distributed load on two slats)

Slat size6' span5' span4' span
100 × 20 mm (H+ reinforced)370 lbs504 lbs745 lbs

How to interpret these results

These results describe performance under the specific test configuration and spans described. They are useful as supporting evidence when comparing spans and reinforcement approaches, but they are not a blanket guarantee for every installation condition.