Fire Resistant Fence: Privacy Aluminum Tested to ASTM E84

The PrimeAlux Privacy Slat fence system, tested for flame spread and smoke

A fire resistant fence claim is only as good as the test behind it. PrimeAlux had its Privacy Slat fence system tested to ASTM E84, the tunnel test for the surface burning characteristics of building materials. It recorded a Flame Spread Index of 0 and a Smoke Developed Index of 50, presented on the product pages as Class A rated for fire and smoke - ASTM E84 (Flame Spread Index 0, Smoke Developed Index 50). This page explains what those figures mean, which product they belong to, and what the test does not tell you.

Get a Privacy fence quote

Or call (437) 333-3032

ASTM E84 Results for the Privacy Slat Fence System

Three figures came out of the test. The full write-up is on the ASTM E84 fire test page.

Flame Spread Index 0

How far and how fast flame travelled along the tested surface, compared with reference materials. Lower numbers mean slower flame spread, and 0 is the low end of the scale.

Smoke Developed Index 50

How much smoke the surface gave off during the test, also on a reference scale. Lower numbers mean less smoke.

What was tested

The PrimeAlux Privacy Slat fence system, which is the Privacy line. The result is not stated for Semi-Privacy or Privacy Plus.

Close view of a brown horizontal slat fence with black posts and the shadow of a tree

How the ASTM E84 Test Works

ASTM E84 is a standard laboratory method. A specimen of the material is mounted in the ceiling of a long, narrow tunnel and exposed to a controlled flame at one end. Over a set time, technicians record how far the flame travels along the surface and measure the smoke that passes through the exhaust.

The results are scored against a reference scale on which inorganic cement board is 0 and red oak is 100. A Flame Spread Index of 0 puts the tested surface at the same end of the scale as the cement board reference.

Want the Privacy line for your yard?

Send the length and height of your fence, and we will quote the Privacy Slat system.

Request a quote Call (437) 333-3032

What an ASTM E84 Result Does Not Tell You

PrimeAlux describes this fence as tested to ASTM E84, and that is the claim. The test measures how flame and smoke behave on a material’s surface in a controlled tunnel. It does not show how a whole fence, its posts and gates behave in a building fire or a wildfire, and it is not a promise that a fence cannot be damaged by fire.

This page also makes no claim that the fence meets any building code, fire code or bylaw. If your property has a fire-related requirement, check it with your municipality or local fire authority, and share the ASTM E84 result with them if it helps.

Black horizontal slat fence panels on a lawn beside a yellow fire hydrant

About the Privacy Aluminum Fence

The Privacy aluminum fence uses panels that close off sightlines. Standard sections are 6 ft wide, and panels come in four standard colours: Walnut, Grey Walnut, Natural Walnut and Grey Brown. Posts are 80 x 80 mm universal 3-way posts that work as middle, end and corner posts.

Aluminum does not absorb moisture, so freeze-thaw cycles do not crack or warp it, and there is no wood to rot and no steel to rust. The slats need only an occasional rinse to stay clean. The PrimeAlux limited warranty lists 15 years for the coated aluminum fence, and it requires documented cleaning twice per year following the PrimeAlux cleaning instructions.

Ready to price a Privacy fence?

Pricing is by quote. Tell us where the fence goes and we will reply in writing.

Get my quote Call (437) 333-3032

Fire Resistant Fence FAQ

Which PrimeAlux fence was tested for fire?

The PrimeAlux Privacy Slat fence system, which is the Privacy aluminum line. It was tested to ASTM E84 and recorded a Flame Spread Index of 0 and a Smoke Developed Index of 50.

Does the fire test apply to Semi-Privacy or Privacy Plus?

No. The ASTM E84 report names the Privacy Slat fence system only. No fire result is stated for the other lines.

Can a fence be completely safe from fire?

PrimeAlux does not describe any fence as immune to fire. The Privacy Slat fence system was tested to ASTM E84, and that test measures surface flame spread and smoke, not how a fence behaves in a real fire.

Does an ASTM E84 result meet my local fire rules?

This page makes no claim about any code, bylaw or wildfire guideline. Check the requirements for your property with your municipality or local fire authority.

Can I order the Privacy fence outside Ontario?

Yes. PrimeAlux delivers across Canada, supply only or with professional installation in Ontario. Aluminum orders typically ship in about a week, subject to current inventory.